Oran Pre-Cast provided a design and build precast frame package on this 8 storey carpark.
ARCHITECT | Silke Architects |
---|---|
ENGINEER | RPS Consulting Engineers |
PRECAST VALUE | €2.5m |
A wide range of precast products were used to form this multi-storey car park. These included rectangular perimeter beams, boot beams and bespoke half-filled composite beams. The stair cores and crash barriers were provided in twinwall. Solid wall panels were utilised in the ramp walls.
Key facts:
-
8 level multi-storey car park, including a double height basement,
-
Maximum bay dimension of 15.6m.
-
150mm, 250mm and 400mm hollowcore.
While the building perimeter stepped back at the upper levels, most of the internal floor layouts were identical at each level. This facilitated a large number of repetitive precast elements. This minimised the number of moulds required, resulting in a cost effective precast solution for the client.